Problem - You have a job to transfer data from source table to target table and you are using some talend input and output database components for example tMSSqlInput and tMSSqloutput. You are interested in finding the rejected rows which are not processed by your tMSSqloutput component
Solution - For this you can use ROWS-->REJECT property of tMSSqlOutput component. Right click on tMSSqlOutput and select Rows-->Reject and then connect this reject flow to your other tFileOutputDelimited component or similar.
(Validated on TIS V 4.0.2)
Solution - For this you can use ROWS-->REJECT property of tMSSqlOutput component. Right click on tMSSqlOutput and select Rows-->Reject and then connect this reject flow to your other tFileOutputDelimited component or similar.
(Validated on TIS V 4.0.2)